Table V

Tests on CWO-11 with Simulated Industrial Wastewater

Experimental conditions: air pressure: 70 kg m–2, temperature: 250ºC, water flow*: 4 l h–1

Wastewater sample O2, % pH COD, mg l–1 TN, mg l–1 Flow rate, l h–1 Exhaust volume, l h–1
Raw wastewater 20.8 9.1 16,483.6 3528 - -
R-1 exit point** 12.2 3.5 7905.4 3.36 4.0 554.4
R-2 exit point 7.9 5.0 414.44 0 3.9 529.4
R-3 exit point 7.1 3.8 16.48 0 3.96 523.4

*Wastewater moves smoothly and continuously, and is not recirculated. **Exit points from Reactors 1, 2 and 3 are shown in Figure 1