Table V
Tests on CWO-11 with Simulated Industrial Wastewater
Experimental conditions: air pressure: 70 kg m–2, temperature: 250ºC, water flow*: 4 l h–1
| Wastewater sample | O2, % | pH | COD, mg l–1 | TN, mg l–1 | Flow rate, l h–1 | Exhaust volume, l h–1 |
|---|---|---|---|---|---|---|
| Raw wastewater | 20.8 | 9.1 | 16,483.6 | 3528 | - | - |
| R-1 exit point** | 12.2 | 3.5 | 7905.4 | 3.36 | 4.0 | 554.4 |
| R-2 exit point | 7.9 | 5.0 | 414.44 | 0 | 3.9 | 529.4 |
| R-3 exit point | 7.1 | 3.8 | 16.48 | 0 | 3.96 | 523.4 |